Argantix XDS Series : Specifications
KDC Series - Models¹
Model Output
Voltage Current RMS Noise
XDS 30-167 0-30 0-167 15mv
XDS 30-333 0-30 0-333 15mv
XDS 30-500 0-30 0-500 15mv
XDS 40-125 0-40 0-125 15mv
XDS 40-250 0-40 0-250 15mv
XDS 40-375 0-40 0-375 15mv
XDS 50-100 0-50 0-100 15mv
XDS 50-200 0-50 0-200 15mv
XDS 50-300 0-50 0-300 15mv
XDS 80-62 0-80 0-62 25mv
XDS 80-125 0-80 0-125 25mv
XDS 80-187 0-80 0-187 25mv
XDS 100-50 0-100 0-50 25mv
XDS 100-100 0-100 0-100 25mv
XDS 100-150 0-100 0-150 25mv
XDS 150-33 0-150 0-33 25mv
XDS 150-66 0-150 0-66 25mv
XDS 150-100 0-150 0-100 25mv
XDS 300-17 0-300 0-17 100mv
XDS 300-33 0-300 0-33 100mv
XDS 300-50 0-300 0-50 100mv
XDS 400-12 0-400 0-12.5 100mv
XDS 400-25 0-400 0-25 100mv
XDS 400-37 0-400 0-37 100mv
XDS 600-8 0-600 0-8 250mv
XDS 600-17 0-600 0-17 250mv
XDS 600-25 0-600 0-25 250mv
Note 1: Contact factory for availability of models with output voltage ranges not listed here.
New Expanded AC Product Line Featuring California Instruments
  Product Configurator  
AC Electronic Loads
AC Modular Supply
Discontinued Products
Product Support
Contact Sales
Output
Power Maximum 5, 10 or 15 KW
Voltage
Accuracy: 0.3 % FS
Resolution: 0.033 % FS
Line Regulation: < 0.1% of V range
Load Regulation: < 0.1% of V range
Transient Response: Voltage will recover to within 2% of V range within 2 msec for 30 % load step.
Stability: ± 0.05% of max. rating per 8 hours after 30 mins. warmup period.
Current Accuracy: 0.5% FS at 0-100% of range
Resolution: 0.1%-0.033 % (model specific)
Line Regulation: < 0.1% of I range
Load Regulation: < 0.1% of I range
Stability: ± 0.05% of max. rating per 8 hours after 30 mins. warmup period.
Input Voltage:
208 - 10 % to 230 + 10% VAC
400 ± 10 % VAC (option -400)
480 ± 10 % VAC (option -480)
All inputs are L-L, 3 phase, 3- wire plus safety ground.

Power Level
Vlow 5 kW 10 kW 15 kW
187 V 27 A 54 A 81 A
360 V 15 A 30 A 45 A
432 V 12 A 24 A 36 A

Current RMS: Typical RMS current per phase at low line input voltage.
Power Factor: > 0.65
Efficiency: > 85 % at full load.

Measurements
Voltage
Model Resolution Accuracy
XDS 30-XXX 0.01 V 0.05 V
XDS 40-XXX 0.01 V 0.05 V
XDS 50-XXX 0.02 V 0.1 V
XDS 80-XXX 0.02 V 0.1 V
XDS 100-XXX 0.1 V 0.2 V
XDS 150-XXX 0.1 V 0.3 V
XDS 300-XXX 0.1 V 0.5 V
XDS 400-XXX 0.1 V 0.5 V
XDS 600-XXX 0.2 V 1.0 V
Voltage
Current Range Resolution Accuracy
0 - 8.3 A 0.003 A 0.013 A
0 - 16 A 0.005 A 0.025 A
0 - 33 A 0.01 A 0.05 A
0 - 66 A 0.02 A 0.1 A
0 - 187 A 0.1 A 0.3 A
0 - 400 A 0.1 A 0.5 A
0 - 600 A 0.2 A 1 A
Power
Range Resolution Accuracy
0 - 5 KW 1 W 0.3 % FS
0 - 10 KW 2 W 0.3 % FS
0 - 15 KW 5 W 0.3 % FS
Peak Current Resolution: See current table
Accuracy: Same as current + 3 x resolution.
Protection Over temperature, short circuit, over current protection
Controls Voltage setting: Digitally encoded rotary knob
Current setting: Digitally encoded rotary knob
Measurement select: Push button
Output on/off: Push button
Power on/off: Toggle switch
Indicators Display: Dual 7 segment large LED
LED’s for: Output on/off, cc mode, cv mode, remote, measurements.

Remote Control
Remote Control A standard RS232C and analog RPV (0-10 VDC) are included with all XDS Series DC Power Supplies. An optional GPIB/IEEE-488 input is available as well.
RS-232C / RS-485
- Standard
9 pin D-shell connector, 115200 baud max., SCPI syntax.
RPV Input - Standard Input: 0-10 VDC for 0-100% range
Connector: 15 pin D-sub.
Remote Inhibit - Standard Programmable for default high or low

-IF Option
IEEE-488 Interface IEEE-488 (GPIB) talker listener.
Subset: AH1, L3, RL2, SH1, T8 IEEE-488.2 SCPI syntax
Environmental
Temperature Coefficient Voltage set point: 0.02%/°C of V Range
Current set point: 0.03%/°C of I Range
Ambient Temperature Operating: 0° to 40° C / 32° to 104° F
Storage: -40° to 75° C / -40° to 167° F
Humidity Operating 0 to 80% RH, non condensing
Cooling Forced air, side and top intake, rear exhaust.

Mechanical
Dimensions Height: 5.25” / 133.35 mm
Width: 19” / 482.6 mm
Depth: 22.19” / 563.3 mm excl. bus bars and cover 24.74” / 628.4 mm incl. bus bars and cover
Weight
Model 15 kW 10 kW 5 kW
Net 90 lbs. 70 lbs. 50 lbs.
41 Kg 32 Kg 23 Kg
Shipping (approx.) 125 lbs. 105 lbs. 85 lbs.
57 Kg 48 Kg 39 Kg
Rack Mounting Unit must be supported by shelf or brackets when mounted in 19” cabinet. No provisions for rack slides are made on instrument.