| Model |
Output |
| Voltage |
Current |
RMS Noise |
| XDS 30-167 |
0-30 |
0-167 |
15mv |
| XDS 30-333 |
0-30 |
0-333 |
15mv |
| XDS 30-500 |
0-30 |
0-500 |
15mv |
| XDS 40-125 |
0-40 |
0-125 |
15mv |
| XDS 40-250 |
0-40 |
0-250 |
15mv |
| XDS 40-375 |
0-40 |
0-375 |
15mv |
| XDS 50-100 |
0-50 |
0-100 |
15mv |
| XDS 50-200 |
0-50 |
0-200 |
15mv |
| XDS 50-300 |
0-50 |
0-300 |
15mv |
| XDS 80-62 |
0-80 |
0-62 |
25mv |
| XDS 80-125 |
0-80 |
0-125 |
25mv |
| XDS 80-187 |
0-80 |
0-187 |
25mv |
| XDS 100-50 |
0-100 |
0-50 |
25mv |
| XDS 100-100 |
0-100 |
0-100 |
25mv |
| XDS 100-150 |
0-100 |
0-150 |
25mv |
| XDS 150-33 |
0-150 |
0-33 |
25mv |
| XDS 150-66 |
0-150 |
0-66 |
25mv |
| XDS 150-100 |
0-150 |
0-100 |
25mv |
| XDS 300-17 |
0-300 |
0-17 |
100mv |
| XDS 300-33 |
0-300 |
0-33 |
100mv |
| XDS 300-50 |
0-300 |
0-50 |
100mv |
| XDS 400-12 |
0-400 |
0-12.5 |
100mv |
| XDS 400-25 |
0-400 |
0-25 |
100mv |
| XDS 400-37 |
0-400 |
0-37 |
100mv |
| XDS 600-8 |
0-600 |
0-8 |
250mv |
| XDS 600-17 |
0-600 |
0-17 |
250mv |
| XDS 600-25 |
0-600 |
0-25 |
250mv |
|
 |
|
 |
| Note 1: Contact factory for availability of models with output voltage ranges not listed here. |
 |
|
 |
|
 |
|
|
| Power
Maximum |
5, 10 or 15 KW |
Voltage
|
Accuracy: 0.3 % FS
Resolution: 0.033 % FS
Line Regulation: < 0.1% of V range
Load Regulation: < 0.1% of V range
Transient Response: Voltage will recover to within
2% of V range within 2 msec
for 30 % load step.
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup
period. |
| Current |
Accuracy: 0.5% FS at 0-100% of range
Resolution: 0.1%-0.033 % (model specific)
Line Regulation: < 0.1% of I range
Load Regulation: < 0.1% of I range
Stability: ± 0.05% of max. rating per 8
hours after 30 mins. warmup
period. |
| Input |
Voltage:
208 - 10 % to 230 + 10% VAC
400 ± 10 % VAC (option -400)
480 ± 10 % VAC (option -480)
All inputs are L-L, 3 phase, 3-
wire plus safety ground.
|
| Vlow |
5 kW |
10 kW |
15 kW |
| 187 V |
27 A |
54 A |
81 A |
| 360 V |
15 A |
30 A |
45 A |
| 432 V |
12 A |
24 A |
36 A |
|
Current RMS: Typical RMS current per
phase at low line input voltage.
Power Factor: > 0.65
Efficiency: > 85 % at full load. |
|
 |
|

|
|
| Voltage |
| Model |
Resolution |
Accuracy |
| XDS 30-XXX |
0.01 V |
0.05 V |
| XDS 40-XXX |
0.01 V |
0.05 V |
| XDS 50-XXX |
0.02 V |
0.1 V |
| XDS 80-XXX |
0.02 V |
0.1 V |
| XDS 100-XXX |
0.1 V |
0.2 V |
| XDS 150-XXX |
0.1 V |
0.3 V |
| XDS 300-XXX |
0.1 V |
0.5 V |
| XDS 400-XXX |
0.1 V |
0.5 V |
| XDS 600-XXX |
0.2 V |
1.0 V |
|
| Voltage |
| Current Range |
Resolution |
Accuracy |
| 0 - 8.3 A |
0.003 A |
0.013 A |
| 0 - 16 A |
0.005 A |
0.025 A |
| 0 - 33 A |
0.01 A |
0.05 A |
| 0 - 66 A |
0.02 A |
0.1 A |
| 0 - 187 A |
0.1 A |
0.3 A |
| 0 - 400 A |
0.1 A |
0.5 A |
| 0 - 600 A |
0.2 A |
1 A |
|
| Power |
| Range |
Resolution |
Accuracy |
| 0 - 5 KW |
1 W |
0.3 % FS |
| 0 - 10 KW |
2 W |
0.3 % FS |
| 0 - 15 KW |
5 W |
0.3 % FS |
|
| Peak Current |
Resolution: See current table
Accuracy: Same as current + 3 x resolution. |
| Protection |
Over temperature, short circuit, over current protection |
| Controls |
Voltage setting: Digitally encoded rotary knob
Current setting: Digitally encoded rotary knob
Measurement select: Push button
Output on/off: Push button
Power on/off: Toggle switch |
| Indicators |
Display: Dual 7 segment large LED
LED’s for: Output on/off, cc mode, cv
mode, remote, measurements. |
|
 |
|

|
|
| Remote Control |
A standard RS232C and analog RPV (0-10 VDC) are
included with all XDS Series DC Power Supplies. An
optional GPIB/IEEE-488 input is available as well. |
RS-232C / RS-485
- Standard |
9 pin D-shell connector, 115200 baud max., SCPI
syntax. |
| RPV Input - Standard |
Input: 0-10 VDC for 0-100% range
Connector: 15 pin D-sub. |
| Remote Inhibit - Standard |
Programmable for default high or low |
|
 |
|

|
|
| IEEE-488 Interface |
IEEE-488 (GPIB) talker listener.
Subset: AH1, L3, RL2, SH1, T8
IEEE-488.2 SCPI syntax |
|
 |
|
 |
|
| Temperature Coefficient |
Voltage set point: 0.02%/°C of V Range
Current set point: 0.03%/°C of I Range |
| Ambient Temperature |
Operating: 0° to 40° C / 32° to 104° F
Storage: -40° to 75° C / -40° to 167° F |
| Humidity
Operating |
0 to 80% RH, non condensing |
| Cooling |
Forced air, side and top intake, rear exhaust. |
|
 |
|

|
|
| Dimensions |
Height: 5.25” / 133.35 mm
Width: 19” / 482.6 mm
Depth: 22.19” / 563.3 mm excl. bus
bars and cover
24.74” / 628.4 mm incl. bus
bars and cover |
| Weight |
| Model |
15 kW |
10 kW |
5 kW |
| Net |
90 lbs. |
70 lbs. |
50 lbs. |
| 41 Kg |
32 Kg |
23 Kg |
| Shipping (approx.) |
125 lbs. |
105 lbs. |
85 lbs. |
| 57 Kg |
48 Kg |
39 Kg |
|
|
| Rack Mounting |
Unit must be supported by shelf or brackets when mounted in 19” cabinet. No provisions for rack slides are made on instrument. |
|
 |
|

|
|
 |