Output Power
Maximum Power Per Phase 3000CS: Single Phase = 3000 VA, Three Phase = 1000 VA. 4500CS: Single Phase = 4500 VA, Three Phase = 1500 VA
Multi-Chassis Maximum Power
Per Phase
9000CS/2: Single Phase = 9000 VA, Three Phase = 3000 VA. 13500CS/3: Single Phase = 13500 VA, Three Phase = 4500 VA.
18000CS/4: Single Phase = 18000 VA, Three Phase = 6000 VA.
Current
Maximum Available Current 3000CS: Single Phase = 44.44 A, Three Phase = 14.81 A. 4500CS: Single Phase = 44.44 A, Three Phase = 14.81 A
Multi-Chassis Maximum Available
Current
9000CS/2: Single Phase = 88.88 A, Three Phase = 29.62 A. 13500CS/3: Single Phase = 133.33 A, Three Phase = 44.44 A.
18000CS/4: Single Phase = 177.7 A, Three Phase = 59.24 A
Programming Resolution 0.01 A
Programming Accuracy Three Phase Mode: ± (0.1% + 0.05 A) from .5A to full scale. Single Phase Mode: ± (0.1% + 0.15 A) from .5A to full scale
Distortion THD (full scale current, resistive load conditions) < 1.2% [60-500 Hz],
< 2% [500-1000 Hz],
< 2.5% [1000-2000 Hz]
Load Regulation 0.1% full scale
Line Regulation 0.02% for 10% input line change
Output Noise (20 kHz to 1 MHz, full current output): Three Phase Mode: < 13 mARMS, Single Phase Mode: < 40 mARMS
Temperature Coefficient ± 0.01% of range / °C
Stability ± 0.01 A over 24 hours
DC Offset Current 0.0 A
Output Coupling Transformer coupled
Output Impedance >100KOhm
Voltage Limit Programming Range: 3000CS: 0 to 135 Vrms @ 7.41 A, 0 to 67.5 Vrms @ 14.81 A. 4500CS: 0 to 135 Vrms @ 11.11 A, 0 to 101.3 Vrms @ 14.81 A
Programming Resolution: 0.1 Vrms
Frequency Range: 45 Hz - 2000 Hz. Resolution: 0.01 Hz [<81.91 Hz], 0.1 Hz [> 82.0 to 819.1 Hz], 1 Hz [> 819 Hz]. Accuracy: ± 0.025%. Temperature Coefficient: ± 5 ppm of value / °C. Stability: ± 15ppm of value/year
Phase Range: Phase B/C relative to phase A 0.0 to 360.0°. Resolution: (0.1° < 819.1 Hz), (0.5° > 819.1 Hz). Accuracy: < 1° [45 Hz-1000 Hz],<1° + 1°/kHz [>1000 Hz]
New Expanded AC Product Line Featuring California Instruments
  Product Configurator  
AC Electronic Loads
AC Modular Supply
Discontinued Products
Product Support
Contact Sales
  Service Agreement for all California Instruments AC except MX & FCS  
Protection
Input Current Input circuit breaker. Breaker protects the equipment only and is not a branch protection device. AC input connection should be made using a suitable branch protection device per local electrical code
Input Voltage Transients Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels
Output Over Voltage Adjustable level constant voltage mode with programmable set point
Open Circuit & Over Temperature Automatic Shutdown
Input
Line Voltage (Three Phase, 3-wire + ground - PE) 3000CS, 4500CS, 9000CS/2, 13500CS/3, 18000CS/4: Standard: 208-230 VLL ± 10%, -400: 400 VLL ± 10%. Note: Each CS chassis requires its own AC service. 3000CS may be operated from 208-230 V L-N single phase AC input between B & C on TB3 for 3000CS
Line VA 3000CS: 5900 VA / 4100 W. 4500CS: 8900 VA / 5900 W (x2 for 9000CS/2, x3 for 13500CS/3, X4 for 18000CS/4)
Line Current
(per phase)
3000CS: Standard: 19 Arms @ 187 VLL, 3 phase AC input or 32 Arms @ 187 VLN single phase AC input.
4500CS: Standard 31 Arms @ 187 VLL, - 400: 16 Arms @ 360 VLL. Currents shown are for single chassis models.
Currents are per chassis for multi-chassis configurations
Line Frequency & Efficiency Line Frequency: 47-440 Hz; Efficiency: 75% (typical) depending on line and load
Power Factor 0.65 (typical)
System
Storage Setup Storage: 16 complete instrument setups; User Waveform Storage: 50 User-defined arbitrary waveforms of 1024 points each; Transient Lists Storage: Up to 100 transient steps per list.
Remote Control Interfaces IEEE-488 (GPIB), USB, RS232C, Ethernet (Optional-LAN)
Input
Parameter Frequency Phase Voltage (AC) Current
(AC rms)
Real Power Apparent Power Power
Factor
Range 45.00-81.91 Hz
82.0-819.1 Hz
> 819 kHz
0-360° 0 - 400 0 - 50 A 0.5 kW 0.5 KVA 0.00 - 1.00
Accuracy* (±) 0.1% + 1 digit 0.5° < 500 Hz
2° > 500 Hz
0.05% + 0.25 V 0.1% + 0.15 A
0.1% + 0.05 A
1ø Mode: 0.15% + 9W
3ø Mode: 0.15% + 3W
1ø Mode: 0.15% + 9 VA
3ø Mode: 0.15% + 3 VA
1ø Mode: 0.03
3ø Mode: 0.01
Resolution 0.01 Hz
0.1 Hz
1 Hz
0.1°
10 mV 1 mA 1 W 1 VA 0.01
* Accuracy specifications are valid above 100 counts. For multi-chassis configurations, Current and Power range and accuracy specifications are per chassis. Frequency measurement accuracy applies to output voltages of 1 Arms or higher
Measurements - Harmonics
Parameter Frequency Fundamental Voltage Current
Range 45-81.91 Hz / 82.0-819.1 Hz / >819 Hz Fundamental Harmonics 2 - 50 Fundamental Harmonics 2 - 50
Accuracy* (±) 0.1% + 1 digit 0.05% + 0.25 V / 0.1% + 0.1%/kHz + 0.25 V 0.5 A / 0.1% + 0.05 A + 0.1% /1 kHz
Resolution 0.01 Hz / 0.1 Hz / 1 Hz 10 mV / 10 mV 10 mA / 10 mA
* Accuracy specifications are in percent of reading for single unit and three phase mode
Physical Dimensions
Dimensions Height: 10.5” (267 mm), Width: 19.0” (483 mm), Depth: 23.0” (584 mm) All dimensions are per chassis. For /2, /3, or /4 model configurations, multiply height by 2, 3, or 4 for total height. Width includes integrated front panel rackmount ears
Weight Chassis: Net: 193 lbs / 87.7 Kg, Shipping: 280 lbs / 127.3 Kg
Vibration and Shock Designed to meet NSTA project 1A transportation levels. Units are shipped in wooden crate with forklift slots
Air Intake/Exhaust Forced air cooling, side air intake, rear exhaust
Temperature Operating Temperature: 0 to 35° C, full power; Storage Temperature: -40 to 85° C