| Power |
3000 W @ 0-37° C; 2400 W @ 38-50° C |
| Current |
30 ARMS |
| Voltage |
50 to 350 VRMS |
| Frequency |
45 to 440 Hz |
| Max. Peak Power |
13 kW (up to 20% duty cycle) |
| Max. Peak/Surge Current |
90 APEAK Surge: 300 APEAK for 50 ms |
| Max. Peak Voltage |
500 VPEAK |
|
 |
|
 |
|
| Constant Current |
Range: 0 to 30 ARMS; Accuracy: 0.2 % of full scale; Resolution: 0.05 % of full scale; Min. Set Current: Voltage / Maximum Set Resistance |
| Constant Voltage |
Range: 50 to 350 VRMS; Accuracy: 0.2 % of full scale; Resolution: 0.05 % of full scale |
| Constant Resistance |
Range: 2.5 to 100 Ohms, 100 to 1000 Ohms; Accuracy: 1% FS, 5% FS; Resolution: 0.05 % FS; Max. Set Resistance: 1 / (Freq.*1.3e-5) |
| Constant Power |
Range: 3000 W @ 0-37° C,2400 W @ 38-50° C; Accuracy: 0.5% of full scale; Resolution: 0.1% of full scale |
| Crest Factor |
Range: 1.4142 to 4.0, limited to 90 Apeak; Accuracy: 1 % of full scale; Resolution: 0.1 % of full scale |
| Power Factor |
Range: 0 to 1 lead or lag limited by Crest factor settings; Accuracy: 1 % of full scale; Resolution: 0.1 % of full scale |
| Short Circuit Mode: |
Max. Surge current: 300 APEAK, up to 50 msec; Max. Cont. current: 30 ARMS; Max. Voltage drop: 2.5 VRMS |
|
 |
|
 |
|
 |
|
 |
|
|
| Frequency |
Range: 45 to 440 Hz; Accuracy: 0.1% FS; Resolution: 0.05% FS |
| Voltage |
Range: 50 to 350 VRMS; Accuracy: 0.1% FS; Resolution: 0.05% FS |
| Peak Voltage |
Range: 50 to 500 V; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| Current |
Range: 0 to 30 ARMS; Accuracy: 0.2% FS; Resolution: 0.1% FS |
| Peak Current |
Range: 0 to 90A; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| Crest Factor |
Range: 1,4142 to 4.0; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| Apparent Power |
Range: 0 to 3000 VA; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| True Power |
Range:0 to 3000 W; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| Peak Power |
Range: 0 to 45,000 W; Accuracy: 1% FS; Resolution: 0.1% FS |
| Reactive Power |
Range: 0 to 3000 VA; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| Power Factor |
Range: 0 to 1; Accuracy: 0.5% FS; Resolution: 0.1% FS |
| Resistance: Range |
2.5 to 100 Ohms,100 to 1000 Ohms; Accuracy: 1% FS, 5% FS; Resolution: 0.05%
FS
Protection
Over |
|
 |
|
 |
|
| Over Current |
Limited by input - Circuit Breaker and Set Maximum Current Limit in software. |
| Over Voltage |
Output protected for voltage transients over 500 V in hardware. |
| Over Power |
Power limited at maximum average and peak rated power in hardware. Limited to Set Maximum Power Limit in software. |
| Over Temperature |
Monitors heat sink temperature. |
|
 |
|
 |
| Mechanical Specifications |
|
| Dimensions |
H: 8.75” (222 mm), W: 16.88” (429 mm), D: 25“ (635 mm) |
| Weight |
74 lbs / 34 Kg. |
| Remote Sensing |
Max. 2V drop between sense and load lines |
| Isolation |
1000 V between input and chassis ground |
| Audible Noise (@1meter) |
Audible Noise (@ 1meter): Low power: 49.0 dBA; Full power: 69.5 dBA |
| Control Power Input |
115 Vac or 230 Vac (model -230) ± 10%, 47 to 63Hz |
| Operating Temperature |
3000 W @ 0-37° C, 2400 W @ 39-50° C |
|
 |
|
 |
|
 |
|
| IEEE-488.2 |
GPIB talker, listener
Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6 |
| Language |
SCPI
RS232C |
| Baud rates: |
9600, 19200, 38400 |
| Handshake |
RTS/CTS |
| Format |
8,n,1 |
| Language |
SCPI |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
 |
|